Steel Fire Retardant Coating Test Furnace Complies with GB14907-2018, Launched by Shenyang Baoruitong

Shenyang Baoruitong GTL-50 fire resistance test furnace for steel structure fire retardant coating, GB14907-2018 compliant, auto temperature curve plotting, 0-360min programmed high temperature test, touch wireless dual control.

[Shenyang, China] – August 9, 2026 – Shenyang Baoruitong Automation Equipment Co., Ltd. officially releases the GTL-50 Steel Structure Fire Retardant Coating Thermal Insulation & Fire Resistance Rating Test Furnace, a professional full-automatic fire test furnace exclusively developed for testing fireproof coatings on steel structures. Fully aligned with GB14907-2018 national standard for steel fire retardant coatings and GB/T9978-2008 fire test clauses, this furnace realizes programmed high-temperature heating, real-time curve recording and full-process unattended testing, becoming core inspection equipment for coating manufacturers, third-party fire labs and construction material R&D institutes.

About Shenyang Baoruitong Automation Equipment Co., Ltd.

Founded in 2012 in Shenyang industrial zone, Shenyang Baoruitong Automation Equipment Co., Ltd. specializes in R&D, manufacturing and export of full-series fire safety testing instruments, including steel fire coating test furnaces, pipe hydrostatic testers, textile vertical flammability testers, cable flame chambers and smoke density test equipment. All products pass ISO9001 & CE certification, strictly complying with GB, ISO, ASTM, UL and EN global standards, widely shipped to Europe, Southeast Asia, North America and Australia for fire certification labs and building material factories.

Core Application & Standard Compliance of GTL-50 Fire Retardant Coating Test Furnace

The GTL-50 furnace is a dedicated testing device to measure thermal insulation efficiency and fire resistance grade of all types of steel fire retardant coatings, strictly following:

  1. GB14907-2018 Fire-retardant coating for steel structures
  2. GB/T9978-2008 Building component fire resistance test clauses 5.1 & 5.2 It supports standard 5005006mm steel plate specimens, simulating real building fire temperature curves up to 1210°C within 6 hours, to judge coating insulation performance, fire endurance and failure time accurately for fire rating certification.

Core Technical Parameters (High SEO Keyword Coverage)

  1. Power supply: AC 220V±10%, 50Hz, total power 3KW
  2. Furnace pressure system: 0-100Pa measuring range, constant furnace pressure control at 20±3Pa
  3. Air flow: 0~50m³/min, measuring accuracy ≤±0.5 m³/min
  4. Fuel type: 0# / -10# diesel for industrial fire testing
  5. Programmed standard fire temperature curves:
    • 60min: Ambient temp → 925℃
    • 120min: Ambient temp → 1050℃
    • 180min: Ambient temp → 1115℃
    • 240min: Ambient temp → 1150℃
    • 300min: Ambient temp → 1180℃
    • 360min: Ambient temp → 1210℃
  6. Thermocouple configuration: 4 furnace temperature K-type thermocouples + 2 unexposed surface thermocouples, back temperature control precision ±4℃
  7. Timing system: 0-360 minutes full range, timing error <±2s
  8. Data storage: Save over 100 groups of complete test data
  9. Specimen size: Standard 500×500×6mm steel plate coated sample
  10. Overall dimension: 1.6m × 1.6m × 1.6m integrated mobile furnace cabinet

Top Selling Points & Product Advantages (Keyword Focused)

1 Touch Screen + Wireless Computer Dual Control System

The steel fire retardant coating test furnace supports standalone touch screen operation without extra PC software installation; built-in wireless communication module realizes remote control. One computer can synchronously control multiple GTL-50 furnaces, and one furnace can receive multi-terminal monitoring, greatly improving lab batch testing efficiency for fireproof coating inspection.

2 Full-Automatic Unattended Fire Test Workflow
  1. Automatic spray diesel ignition & auto re-ignition when flame extinguishes during high-temperature testing
  2. Auto stop heating once preset fire resistance time/temperature is reached
  3. Real-time automatic plotting of furnace temperature curve & furnace pressure curve
  4. Automatic exhaust air and forced cooling after test completion
  5. Auto screen identification & elimination of faulty thermocouple signals, avoiding invalid test data
  6. Anti-power-off protection design: test data auto saved, equipment protected from sudden power failure damage
3 Ultra-High Testing Precision, Error Lower Than National Standard

Adopts Class II nickel-chromium/nickel-silicon K-type sheathed thermocouples, dual monitoring of furnace internal temperature and specimen back unexposed surface temperature. Users can choose average back temperature or single-point temperature for control, all temperature deviation indexes are superior to GB14907-2018 standard limits, ensuring authoritative, audit-ready test reports for fire retardant coating certification.

4 Large Data Storage & Traceable Test Records

Built-in large-capacity memory supports storage of more than 100 groups of complete test data, including temperature curves, pressure records, timing logs and coating insulation index data. All historical test files can be exported for third-party certification audit, ideal for fire coating factory QC labs and accredited testing institutions.

5 Integrated Mobile Compact Furnace Cabinet

All-in-one 1.6m cubic furnace body with bottom moving casters, easy to transport and place in small fire test labs. Fully automatic spray heating system with stable diesel combustion, uniform furnace temperature field, no local overheating affecting steel fire coating test results.

Wide Application Scenarios

  • Steel structure fire retardant coating manufacturers daily quality inspection
  • Intumescent fireproof coating & thin/thick type fire coating R&D laboratories
  • ISO 17025 accredited construction fire safety testing laboratories
  • Architectural design institutes and building material supervision departments
  • Fire protection engineering companies for coating performance verification
  • University fire engineering material research labs

About Shenyang Baoruitong Automation Equipment Co., Ltd.

Shenyang Baoruitong Automation Equipment Co., Ltd. specializes in R&D and production of construction fire test equipment, including GTL-50 steel fire retardant coating test furnace, vertical/horizontal fire resistance furnace, cone calorimeter, bomb calorimeter, plastic pipe hydrostatic tester, textile flammability tester and cable flame test chamber. All fire test machines pass factory high-temperature aging test, provide on-site installation, operation training and long-term calibration maintenance service for global clients.

Download GTL-50 technical datasheet, GB14907-2018 matching operation manual and get customized quotation via official website inquiry page.