Description
ZXLR Cone Calorimeter | ISO 5660 GB/T 16172 Building Material Heat Release Rate Fire Test Machine
1. Product Overview
2. Compliant Global & Domestic Standards
National Standard
- GB/T 16172-2026 Test method for heat release rate and smoke production rate of building materials
International Standards
- ISO 5660-1 Reaction-to-fire tests — Heat release rate (cone calorimeter method)
- ISO 5660-2 Reaction-to-fire tests — Dynamic smoke production rate measurement
ASTM Standards
- ASTM E1354 Oxygen consumption calorimeter for heat & visible smoke release
- ASTM E1474 Upholstered furniture & mattress composite fire testing
- ASTM E1740 Interior wall lining materials test
- ASTM D1550 Institutional mattress fire test
- ASTM D6113 Wire & cable flammability assessment
Industry & Maritime Standards
- BS 6873 Railway vehicle fire test
- IMO International Maritime Organization fire safety test specifications
3. Core Technical Specifications
3.1 Radiant Cone Heater
- Imported high-temperature electric heating tube for stable long-term heating
- Rated power: 5000 W; adjustable radiant heat flux: 0–100 kW/m²
- Double-layer heat-resistant cone jacket filled with 13 mm thick, 100 kg/m³ heat-resistant fiber
- Uniform radiant intensity: center deviation ≤ ±2%; customizable heat flux for different test protocols
- 3 symmetrically mounted K-type thermocouples for temperature monitoring, non-weld contact with heating tube
- PID+SSR closed-loop temperature control, temperature accuracy ±10℃, automatic flux compensation
- 3.0 mm exposed hot junction K-type sheathed thermocouple for irradiance calibration
3.2 Automatic Radiation Shield
- 6 mm thick non-water-cooled stainless steel construction, high temperature resistance
- Fully computerized automatic insertion & retraction via program signals, no manual operation
3.3 High Precision Weighing System
- Integrated double thermal insulation structure, keeps load cell at ambient temperature to extend service life
- Weighing range: 0–1000 g
- Weighing accuracy: 0.1 g
- Fast response time: < 4 seconds
- Stable signal output: drift ≤ 1 g within 30 minutes during calibration
4. Key Measurable Test Parameters
- Heat Release Rate (HRR) – core index for fire hazard grading
- Time to Ignition & ignition temperature
- Critical heat flux for sustained ignition
- Specimen mass loss rate & total mass loss
- Smoke production rate & total smoke output
- Effective heat of combustion
- Toxic gas release rate (CO, CO₂ and other combustion products)
5. Main Product Features
Full Global Standard Compatibility
Supports GB, ISO, ASTM, BS, IMO and railway fire test standards, test data recognized for global product certification across construction, furniture, cable, marine and rail industries.
High-Uniformity Radiant Cone Heating System
5kW imported heating tube with double-layer heat insulation, radiant intensity deviation ≤ ±2%, PID precise temperature control ensures consistent thermal radiation for repeatable test results.
Dual Independent Touch & Computer Control
Integrated touch screen operation + PC software linkage; real-time data display, automatic curve plotting of HRR, smoke, mass and gas concentration, one-click test report export.
Thermally Isolated Precision Weighing Module
Double thermal barrier design protects the weighing sensor from high-temperature radiation, delivering 0.1g ultra-precise mass loss tracking with stable long-run calibration.
Fully Automated Test Workflow
Automatic radiation shield retraction/insertion, auto ignition monitoring, continuous gas & smoke sampling, automatic data storage and curve generation with minimal manual intervention.
Integrated Gas & Smoke Analysis Unit
Built-in gas sampling pipeline with drying & filtering modules, real-time detection of carbon oxides and smoke density to evaluate secondary fire hazards from toxic fumes.
Stable & Durable Stainless Steel Structure
High-temperature resistant stainless steel cone, shield and test chamber, anti-corrosion and easy to clean after combustion tests.
Large-Capacity Data Storage & Report Generation
Automatically save complete test records, time-series curves and calculation results; customizable export of standardized test reports for laboratory archives and third-party certification.
6. Target Application & End Users
- Construction material manufacturers (wood, plastic, wall panels, insulation boards)
- Wire & cable, foam, textile and upholstered furniture factories
- Third-party fire safety testing & certification laboratories
- Marine, railway, automotive component R&D institutes
- University fire safety & material science research labs
- Government construction inspection institutions
7. Why Choose ZXLR Cone Calorimeter
✅ Passes GB/T 16172-2026 & ISO 5660-1 core standards, compatible with ASTM, BS, IMO global test protocols
✅ 5000W uniform radiant cone with ±2% flux deviation, industry-leading heating stability
✅ Double heat-insulated weighing sensor with 0.1g precision for accurate mass loss measurement
✅ Full automatic program control, auto shield movement, real-time smoke & toxic gas monitoring
✅ All-in-one integrated cabinet with built-in gas treatment, easy installation and lab layout
✅ Complete data curve recording & editable test report output for certification submission
✅ Durable stainless steel high-temperature components, low maintenance cost and long service life