ISO 1716 GB/T 14402 JRZ10 Bomb Calorimeter | Gross Heat of Combustion Tester for Building Materials

JRZ10 oxygen bomb calorimeter complies with ISO 1716:2018 & GB/T 14402-2026. It measures gross combustion calorific value of building materials, coal, wood and chemicals with ultra-high 0.0001℃ temperature resolution.

Description

JRZ10 Building Material Combustion Calorific Value Determination Apparatus

1. Product Overview

The JRZ10 Building Material Combustion Calorific Value Determination Apparatus is a fully automated constant-temperature oxygen bomb calorimeter integrated with professional microcomputer control system. Controlled by dedicated Windows test software, it automatically completes full testing, data acquisition and result calculation.
This lab instrument accurately measures the gross heat of combustion (total calorific value) of combustible samples, covering building materials, coal, petroleum products, chemicals, timber, food and explosive materials. It is core equipment for fire hazard classification of construction materials, raw material quality inspection, fuel energy detection and material combustion performance research, widely used in third-party fire certification labs, construction material factories, energy testing institutions and university research labs.

2. Applicable Global & National Standards

  1. GB/T 14402-2026 Reaction to Fire Tests for Building Products – Determination of the Gross Heat of Combustion
  2. ISO 1716:2018 Determination of the Gross Calorific Potential (PCS) of Building Materials
  3. GB/T 213-2008 Standard test method for calorific value of solid fuels

3. Core Technical Specifications

  1. Temperature Measuring Range: 0 ~ 40℃; temperature fluctuation during single test ≤ 1℃
  2. Relative Humidity Working Condition: ≤85%
  3. Ultra-high Temperature Resolution: 0.0001℃
  4. Standard Test Cycle: 18–20 minutes total
    • 6 mins pre-test water temperature balance
    • 12 mins post-ignition main temperature measurement
       
      *Low-calorific-value coal samples require extended testing time
  5. Power Supply: AC 220V±10V, Rated Power < 500W
  6. Overall Equipment Size: 400 mm × 575 mm × 456 mm
  7. Water Vessel Configuration: Outer tank 35L, inner tank 2.3L
  8. Ignition Voltage: 24V
  9. Measurement Accuracy: Fully meets GB/T 213-2008 national standard requirements
  10. Water balancing repeatability error: < 0.5 g

4. Main Product Features

  1. Full Standard Compliance for Global Fire Certification
     
    Strictly manufactured to ISO 1716:2018 and GB/T 14402-2026, test data recognized for building material fire performance classification and international certification reports.
  2. Fully Automatic Unattended Test Workflow
     
    Simple manual preparation only: load sample into oxygen bomb, fill oxygen, place bomb into calorimeter tank; the whole testing, stirring, temperature recording and data calculation run automatically without manual monitoring.
  3. Dual-Layer Double Vessel Water Tank Structure
     
    Independent inner and outer water tank design prevents water overflow during filling, ensures stable constant-temperature environment to eliminate external temperature interference and improve test repeatability.
  4. Precision Water Level Balancing System
     
    Equipped with dedicated water balance box, water feeding repeatability error less than 0.5g, consistent water volume for every test to reduce data deviation and shorten testing cycle.
  5. Imported High-Speed Circulation Stirring Motor
     
    High-efficiency imported stirring unit realizes fast uniform water circulation inside inner tank, rapid heat exchange to guarantee accurate temperature reading.
  6. Stable Windows PC Control Software
     
    Dedicated matching test software compatible with all Windows systems, intuitive operation interface, automatic curve plotting, one-click data storage, report generation and export, easy to learn for lab operators.
  7. Premium Assembly & Low Failure Rate
     
    High-quality structural materials, exquisite manufacturing process, compact integrated cabinet layout, stable long-term operation with minimal maintenance.
  8. Wide Sample Compatibility
     
    Supports calorific value testing of building materials, coal, fuel oil, chemical raw materials, wood, food and energetic substances, multi-scenario lab application.

5. Application & Target Customers

  • Construction & decorative building material manufacturers
  • Third-party fire safety testing and certification laboratories
  • Coal, fuel and energy quality inspection institutions
  • Chemical, new material and flame retardant R&D factories
  • University fire safety, energy and material science research labs
  • Construction engineering quality supervision departments

6. Why Choose JRZ10 Bomb Calorimeter

✅ Meets ISO 1716 and GB/T 14402 standards for building material gross combustion heat testing, valid for global fire grading certification
✅ Ultra-fine 0.0001℃ temperature resolution ensures high-precision, repeatable calorific value data
✅ Fully automatic test process, only simple sample prepping needed to save lab labor cost
✅ Double water tank + precision water balance system minimizes external temperature interference
✅ Imported stirring motor for fast uniform heat exchange and stable temperature detection
✅ User-friendly Windows supporting software with automatic report & curve generation
✅ Compact desktop size, low power consumption (<500W), stable performance and low maintenance cost
✅ Wide sample applicability covering construction materials, fuels, chemicals and timber