Description
FCZ-50 Textile Vertical Flammability Tester | GB/T 5455-2014 Vertical Burn Test Machine for Fabrics
1. Product Overview
The FCZ-50 Textile Vertical Flammability Tester is a professional laboratory instrument strictly developed in accordance with GB/T 5455-2014 Textiles – Burning Behaviour – Determination of Damaged Length, Afterglow Time and Afterflame Time of Vertically Oriented Specimens.
This vertical combustion testing machine is specially designed to evaluate the fire performance of all types of textiles and finished textile products. It accurately measures three core flammability indicators: afterflame time, afterglow time and char damaged length of vertical fabric samples, providing reliable standardized test data for textile factories, garment manufacturers, third-party fire testing labs and textile material R&D institutions.
2. Applicable Standard
GB/T 5455-2014 Textiles – Burning Behaviour – Determination of Damaged Length, Afterglow Time and Afterflame Time of Vertically Oriented Specimens
3. Core Technical Specifications
- Combustion Chamber Internal Size: (329 ± 2) mm × (329 ± 2) mm × (767 ± 2) mm
- Specimen Holder Inner Size: 356 mm × 51 mm
- Ignition Bunsen Burner: Nozzle inner diameter 11 mm
- Working Environment: Temperature 10~30℃, Relative Humidity 30%~80%
- Measurement Resolution: Time 0.1 s; Length 1 mm
- Power Supply: AC 220V, 50Hz, Rated Power 100W
- Overall Equipment Dimension: 632 mm × 332 mm × 852 mm
Two Standard Test Conditioning Modes
Condition A (Standard Atmosphere Conditioning)
- Specimen Size: 300 mm × 89 mm
- Specimen Quantity: 5 warp + 5 weft, total 10 pieces
- Test Gas: Industrial propane / butane / mixed gas
- Fixed Ignition Time: 12 seconds
Condition B (Oven Dry Conditioning)
- Specimen Size: 300 mm × 89 mm
- Specimen Quantity: 3 warp + 2 weft, total 5 pieces
- Test Gas: Methane (purity ≥97%)
- Fixed Ignition Time: 3 seconds
Note: Test results from Condition A and Condition B are not interchangeable.
Standard Weight Matching for Fabric Samples
Different counterweights are matched according to fabric mass per unit area to measure damaged length accurately:
- ≤101 g/m²: 54.5 g weight
- 101 ~ 207 g/m²: 113.4 g weight
- 207 ~ 338 g/m²: 226.8 g weight
- 338 ~ 650 g/m²: 340.2 g weight
- ≥650 g/m²: 453.6 g weight
4. Main Product Features
- Full Compliance with GB/T 5455-2014 StandardFully matched chamber size, burner size, ignition time and specimen requirements, test data valid for domestic textile fire safety certification.
- Touch Screen Intelligent Control SystemEquipped with MCGS touch screen for one-touch operation; real-time display of gas pressure, test timing and all flammability data, intuitive and easy to operate.
- Two Independent Standard Test Modes Built-InSupports Condition A and Condition B two full sets of standard test procedures, automatically matching ignition time and applicable fuel gas for different conditioning requirements.
- High Precision Measurement System0.1s time resolution for afterflame & afterglow timing, 1mm length resolution for char damaged length, effectively eliminating manual reading errors.
- Stable Gas Pressure MonitoringBuilt-in pressure gauge to real-time monitor fuel gas pressure, ensure stable flame height and consistent ignition condition for repeatable test results.
- Transparent Observation Window Safety ChamberSealed combustion cabinet with large transparent viewing window, operators can observe fabric combustion state clearly without opening the door, improving testing safety.
- Complete Matching Auxiliary WeightsComes with full set of standard counterweights covering all fabric grammage ranges, convenient for quick specimen damaged length measurement after testing.
- Compact Desktop Integrated StructureSmall overall footprint, low power consumption (100W only), easy to install, move and maintain in small & medium textile laboratories.
5. Application & Target Customers
- Textile raw material & fabric manufacturers
- Garment, bedding, curtain and upholstery fabric factories
- Third-party textile fire safety testing laboratories
- Textile material research & development labs
- Inspection institutions for textile quality supervision
6. Why Choose FCZ-50 Textile Vertical Flammability Tester
✅ Strictly designed per GB/T 5455-2014 standard, fully compliant with national textile vertical burn test requirements
✅ Dual built-in test modes (Condition A & B) to cover all standard conditioning test demands
✅ MCGS touch screen + real-time gas pressure gauge for stable, simple operation
✅ Ultra-fine precision timing & length measurement guarantees accurate flammability data
✅ Complete supporting standard weights for all fabric grammage testing
✅ Sealed transparent combustion chamber improves operation safety and observation visibility
✅ Low power consumption, compact desktop design, cost-effective for textile factory QC labs
✅ Dual built-in test modes (Condition A & B) to cover all standard conditioning test demands
✅ MCGS touch screen + real-time gas pressure gauge for stable, simple operation
✅ Ultra-fine precision timing & length measurement guarantees accurate flammability data
✅ Complete supporting standard weights for all fabric grammage testing
✅ Sealed transparent combustion chamber improves operation safety and observation visibility
✅ Low power consumption, compact desktop design, cost-effective for textile factory QC labs